TL-SG2210MP

Switch Smart con 8 Porte Gigabit PoE+ e 2 Slot SFP | Jetstream by Omada

  • Switch Gigabit PoE+ - Switch dotato di 10 porte Gigabit - 8 PoE+ e 2 SFP.
  • Power Budget totale - Alimentazione PoE+ 802.3at/af-compliant fino a 150 W su tutte le 8 porte PoE+.*
  • Dispositivo integrato Omada SDN* - La nuova soluzione Omada Software Defined Networking consente di gestire le reti Omada con modalità Hybrid Cloud e Full-Cloud. Integra Access Point della serie EAP, Router VPN SafeStream e Switch JetStream by Omada.
  • App Omada - L'intuitiva app Omada, per dispositivi Android e iOS, consente di accedere da remoto alla rete tramite Cloud, in qualunque momento, ovunque ti trovi.
  • Massima sicurezza - IP-MAC-Port Binding, ACL, Port Security, DoS Defend, Storm Control, DHCP Snooping, 802.1X, Radius Authentication, ecc.
  • Ottimizzazione video/voce - Con funzionalità L2/L3/L4 QoS e IGMP snooping.

Learn more about TP-Link PoE technology >

 

Learn more about Omada Cloud SDN>​

  • What is Omada Cloud SDN?

  • Introducing TP-Link PoE Switches

TP-Link | Omada Software Defined Networking

Switch PoE+ per installazioni flessibili e reti altamente scalabili

Switch JetStream 10 Porte Gigabit: 2 SFP - 8 PoE+

TL-SG2210MP

  •  

    Gestione centralizzata in Cloud

    Dispositivo integrato Omada SDN

  •  

    Funzionalità Layer L2

    L2/L3/L4 QoS, ACL, IGMP Snooping

  •  

    Massima sicurezza

    LAN Area Investment Protection

  •  

    Supporto PoE+

    8 Porte PoE+ - Power budget totale 150 W*

Omada SDN - Software Defined Networking

Omada SDN è la soluzione Software Defined di TP-Link che offre soluzioni wireless e cablate ideali per strutture alberghiere e sanitarie, edifici scolastici, aziende, spazi pubblici e molto altro. Omada SDN integra una gamma completa di dispositivi - Access Point, Switch, Gateway e Hardware Controller - in una soluzione altamente scalabile con gestione Full-Cloud e Hybrid-Cloud.

JetStream Switches SafeStream Gateways Omada Access Points Wi-Fi 6 Indoor
 Wall
Plate
Outdoor Nuova interfaccia di gestione Hardware Controller Gestione Full-Cloud
Continua >

Case History

  • Many network technologies such as XGS-PON help Covid-19 Vaccine Center

    Many network technologies such as XGS-PON help Covid-19 Vaccine Center

    Many network technologies such as XGS-PON help Covid-19 Vaccine Center

    Many network technologies such as XGS-PON help Covid-19 Vaccine Center

  • Istituto Superiore Statale Del Rosso - Da Verrazzano

    TP-Link Professional Solution in ambito Education per Istituto Superiore Statale Del Rosso - Da Verrazzano. Progetto realizzato da TP-Link Partner Fans Computer.

    Istituto Superiore Statale Del Rosso - Da Verrazzano

    TP-Link Professional Solution in ambito Education per Istituto Superiore Statale Del Rosso - Da Verrazzano. Progetto realizzato da TP-Link Partner Fans Computer.

  • Capovaticano Resort Thalasso SPA

    TP-Link Professional Solution in ambito Hospitality per Capovaticano Resort Thalasso SPA. Progetto realizzato da TP-Link Gold Partner Aetherna.

    Capovaticano Resort Thalasso SPA

    TP-Link Professional Solution in ambito Hospitality per Capovaticano Resort Thalasso SPA. Progetto realizzato da TP-Link Gold Partner Aetherna.

  • Centro Vaccinale di Novegro

    TP-Link Professional Solution in ambito Healthcare per il Centro Vaccinale di Novegro. Progetto realizzato da TP-Link Partner POL-ONE S.r.l.

    Centro Vaccinale di Novegro

    TP-Link Professional Solution in ambito Healthcare per il Centro Vaccinale di Novegro. Progetto realizzato da TP-Link Partner POL-ONE S.r.l.

    Pol-One i partner installatori: “TP-Link ha fornito i dispositivi di rete indispensabili per la realizzazione delle postazioni informatizzate del Centro Vaccinale, che consentono di operare in modo rapido e sicuro durante tutte le fasi, dal processo di accettazione dei pazienti fino alla registrazione e certificazione dell’avvenuta vaccinazione. L’infrastruttura realizzata consente di sfruttare al massimo la velocità di connessione disponibile, snellendo notevolmente i tempi necessari a completare le pratiche amministrative.”
CARATTERISTICHE HARDWARE
Standard e protocolli IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE802.3z, IEEE 802.3ad, IEEE 802.3x, IEEE 802.3af, IEEE 802.3at, IEEE 802.3az, IEEE 802.1d, IEEE 802.1s, IEEE 802.1w, IEEE 802.1q, IEEE 802.1x, IEEE 802.1p
Interfaccia • 8× 10/100/1000 Mbps RJ45 Ports, all supporting PoE+ (Auto-Negotiation/Auto MDI/MDIX)
• 2× 100/1000 Mbps SFP Slots
Media • 10BASE-T: UTP/STP category 3, 4, 5 cable (maximum 100m)
• 100BASE-TX/1000Base-T: UTP/STP category 5, 5e or above cable (maximum 100m)
• 100BASE-FX: MMF, SMF
• 1000BASE-X: MMF, SMF
Numero ventole 1
Physical security lock Yes
Alimentazione 100-240V AC, 50/60Hz
Porte PoE • Standard: 802.3at/af compliant
• PoE+ Ports: 8 Ports
• PoE Power Budget: 150 W*
Dimensioni ( L x P x A ) 294 x 180 x 44 mm
Tipo di montaggio Rackmount/Desktop
Max Power Consumption • V1: 173.9 W (110 V/60 Hz) (with 150 W PD connected); 12.2 W (110 V/60 Hz) (no PD connected)
• V2: 169.5 W (220 V/50Hz) (with 150 W PD connected)
• V3: 175.3 W (110 V/60Hz) (with 150 W PD connected)
• V4: 174.2 W (110V/60Hz) (with 150 W PD connected)
Max Heat Dissipation • V1: 41.63 BTU/h (with no PD connected); 539.35 BTU/h (with 150 W PD connected)
• V2: 578.42 BTU/hr (220V/50 Hz) (with 150 W PDconnected)
• V3: 597.8 BTU/hr (110 V/60 Hz) (with 150 W PD connected)
• V4: 594.46 BTU/hr (110V/60Hz) (with 150 W PD connected)
PRESTAZIONI
Capacità di switching 20 Gbps
Packet Forwarding Rate 14.9 Mpps
Tabella ARP 8K
Buffer (pacchetti) 4.1 Mbit
Jumbo frame 9 KB
CARATTERISTICHE SOFTWARE
QoS (Quality of Service) • 802.1p CoS/DSCP priority
• 8 priority queues
• Priority Schedule Mode
- SP (Strict Priority)
- WRR (Weighted Round Robin)
• Queue Weight Config
• Bandwidth Control
- Port/Flow based Rating Limit
• Smoother Performance
• Storm Control
- Multiple Control Modes(kbps/ratio)
- Broadcast/Multicast/Unknown-Unicast Control
Funzionalità L2 e L2+ • DHCP Relay
- DHCP VLAN Relay
• DHCP L2 Relay
• Link Aggregation
- Static link aggregation
- 802.3ad LACP
- Up to 8 aggregation groups and up to 8 ports
per group
• Spanning Tree Protocol
- 802.1D STP
- 802.1w RSTP
- 802.1s MSTP
- STP Security: TC Protect, BPDU Filter/Protect,
Root Protect
• Loopback Detection
• Flow Control
- 802.3x Flow Control
• Mirroring
- Port Mirroring
- CPU Mirroring
- One-to-One
- Many-to-One
- Flow-Based
- Ingress/Egress/Both
• Device Link Detect Protocol (DLDP)
• 802.1ab LLDP/ LLDP-MED
L2 Multicast • 511 IPv4, IPv6 shared multicast groups
• IGMP Snooping
- IGMP v1/v2/v3 Snooping
- Fast Leave
- IGMP Snooping Querier
- Static Group Config
• Multicast VLAN Registration (MVR)
• Multicast Filtering
• MLD Snooping
- MLD v1/v2 Snooping
- Fast Leave
- MLD Snooping Querier
- Static Group Config
• Limited IP Multicast (256 profiles and 16 entries per profile)
Caratteristiche avanzate • Automatic Device Discovery
• Batch Configuration
• Batch Firmware Upgrading
• Intelligent Network Monitoring
• Abnormal Event Warnings
• Unified Configuration
• Reboot Schedule
VLAN • VLAN Group
- Max. 4K VLAN Groups
• 802.1Q tag VLAN
• MAC VLAN: 12 Entries
• Protocol VLAN
• GVRP
• Voice VLAN
ACL (Access Control List) • Support up to 230 entries
• Time-Range
- Time Slice
- Week Time-Range
- Absolute Time-Range
- Holiday
• Time-based ACL
• MAC ACL
- Source MAC
- Destination MAC
- VLAN ID
- User Priority
- Ether Type
• IP ACL
- Source IP
- Destination IP
- IP Protocol
- TCP Flag
- TCP/UDP Source Port
- TCP/UDP Destination Port
- DSCP/IP TOS
• IPv6 ACL
• Combined ACL
• Rule Operation
- Permit/Deny
• Policy Action
- Mirror
- Rate Limit
- Redirect
- QoS Remark
• ACL Rules Binding
- Port Binding
- VLAN Binding
• Actions for flows
- Mirror (to supported interface)
- Redirect (to supported interface)
- Rate Limit
- QoS Remark
Sicurezza • AAA
• 802.1X
- Port based authentication
- MAC (Host) based authentication
- Authentication Method includes PAP/EAP-MD5
- MAB
- Guest VLAN
- Support Radius authentication and
accountability
• IP/IPv6-MAC Binding
- 512 Binding Entries
- DHCP Snooping
- DHCPv6 Snooping
- ARP Inspection
- ND Detection
• IP Source Guard
- 253 Entries
- Source IP+Source MAC
• IPv6 Source Guard
- 183 Entries
- Source IPv6 Address+Source MAC
• DoS Defend
• Static/Dynamic/Permanent Port Security
- Up to 64 MAC addresses per port
• Broadcast/Multicast/Unicast Storm Control
- kbps/ratio control mode
• Port Isolation
• Secure web management through HTTPS with
SSLv3/TLS 1.2
• Secure Command Line Interface (CLI)
management with SSHv1/SSHv2
• IP/Port/MAC based access control
IPv6 • IPv6 Static Routing and ACL
• IPv6 Dual IPv4/IPv6
• IPv6 Interface
• Multicast Listener Discovery (MLD) Snooping
• IPv6 neighbor discovery (ND)
• Path maximum transmission unit (MTU) discovery
• Internet Control Message Protocol (ICMP)
version 6
• TCPv6/UDPv6
• IPv6 applications
- DHCPv6 Client
- Ping6
- Tracert6
- Telnet(v6)
- IPv6 SNMP
- IPv6 SSH
- IPv6 SSL
- Http/Https
- IPv6 TFTP
MIBs • MIB II (RFC1213)
• Bridge MIB (RFC1493)
• P/Q-Bridge MIB (RFC2674)
• Radius Accounting Client MIB (RFC2620)
• Radius Authentication Client MIB (RFC2618)
• Remote Ping, Traceroute MIB (RFC2925)
• Support TP-Link private MIBs
• RMON MIB(RFC1757, rmon 1,2,3,9)
GESTIONE
Omada App Yes, through
• Omada Cloud-Based Controller
• OC300
• OC200
• Omada Software Controller
Centralized Management • Omada Cloud-Based Controller
• Omada Hardware Controller (OC300)
• Omada Hardware Controller (OC200)
• Omada Software Controller
Cloud Access Yes, through
• Omada Cloud-Based Controller
• OC300
• OC200
• Omada Software Controller
Zero-Touch Provisioning Yes. Requiring the use of Omada Cloud-Based Controller.
Management Features • Web-based GUI
• Command Line Interface (CLI) through telnet
• SNMPv1/v2c/v3
• SNMP Trap/Inform
• RMON (1,2,3,9 groups)
• SDM Template
• DHCP/BOOTP Client
• Dual Image, Dual Configuration
• CPU Monitoring
• Cable Diagnostics
• EEE
• SNTP
• System Log
ALTRO
Certificazione CE, FCC, RoHS
Contenuto della confezione • TL-SG2210MP
• Power Cord
• Installation Guide
• Rackmount Kit
• Rubber Feet
Requisiti di sistema Microsoft® Windows® 98SE, NT, 2000, XP, Vista™ or Windows 7/8/10, MAC® OS, NetWare®, UNIX® or Linux.
Ambiente • Operating Temperature: 0–50 ℃ (32–122 ℉);
• Storage Temperature: -40–70 ℃ (-40–158 ℉)
• Operating Humidity: 10–90% RH non-condensing
• Storage Humidity: 5–90% RH non-condensing

*Il calcolo del Power Budget PoEsi basa su test di laboratorio. Le prestazioni possono variare in base a limitazioni dei client e fattori ambientali.

* Verifica a questo link le funzionalità switch disponibili con Omada SDN.