TL-SG2218
NovoJetStream 16-Port Gigabit Smart Switch with 2 SFP Slots
- Full Gigabit Ports: 16× gigabit RJ45 ports and 2× gigabit SFP Slots provide high-speed connections.
- Integrated into Omada SDN: Zero-Touch Provisioning (ZTP)*, Centralized Cloud Management, and Intelligent Monitoring.
- Centralized Management: Cloud access and Omada app for ultra convenience and easy management.
- Static Routing: Helps route internal traffic for more efficient use of network resources.
- Robust Security Strategies: IP-MAC-Port Binding, ACL, Port Security, DoS Defend, Storm control, DHCP Snooping, 802.1X, Radius Authentication, and more.
- Optimize Voice and Video Applications: L2/L3/L4 QoS and IGMP snooping.
- Standalone Management: Web, CLI (Telnet, SSH), SNMP, RMON, and Dual Image bring powerful management capabilities
Centralized Management
Convenient Gigabit Switch
for a Complete Omada Network
JetStream 16-Port Gigabit Smart Switch with 2 SFP Slots
TL-SG2218
-
Reliable Gigabit Connections
16× Gigabit RJ45 Ports and
2× Gigabit SFP Ports -
Centralized Cloud Management
SDN Solutions Integration for
a Highly Efficient Network -
Abundant Secure Strategies
LAN Area Investment Protection
-
Advanced L2+ Features
L2/L3/L4 QoS, ACL,
Static Routing and More
Software Defined Networking (SDN) with Cloud Access
Omada’s Software Defined Networking (SDN) platform integrates network devices, including access points, switches and gateways, providing 100% centralized cloud management. Omada creates a highly scalable network—all controlled from a single interface. Seamless wireless and wired connections are provided, ideal for use in hospitality, education, retail, offices, and more.
-
Hassle-Free Cloud or
On-Premises Controllers -
Multi-Site Cloud
Management -
Zero-Touch
Provisioning (ZTP)* -
Intelligent
Monitoring
Advanced L3 Features**
An abundance of L2+ and L3 features are supported to help build a highly scalable and robust network, providing a reliable and efficient solution for enterprises, campuses and ISPs.
Secure Networking
Security features include IP-MAC-Port-VID Binding, Port Security, Storm Control and DHCP Snooping to defend against a range of network threats. An integrated list of common DoS attacks is available, making it easier than ever to prevent them. In addition, the Access Control Lists (ACL, L2 to L4) feature restricts access to sensitive network resources by denying packets based on source and destination MAC address, IP address, TCP/UDP ports or VLAN ID. Users’ network access can be controlled via 802.1X authentication, which works with a RADIUS/Tacacs+ server to grant access only when valid user credentials are provided.
Enterprise Level Features
A complete lineup of L2+ features are supported, including 802.1Q VLAN, Port Mirroring, STP/RSTP/MSTP, Link Aggregation Control Protocol, and 802.3x Flow Control. Advanced IGMP Snooping ensures the switch intelligently forwards multicast streams to only the appropriate subscribers, cutting out unnecessary traffic, while IGMP throttling & filtering restrict each subscriber on a port level to prevent unauthorized multicast access. Static Routing is a simple way of segmenting the network and internally routs traffic through the switch for improved efficiency.
Advanced QoS
Voice and video traffic can be prioritized based on IP address, MAC address, TCP port number, UDP port number, and more. With QoS (Quality of Service), voice and video services remain smooth, even when bandwidth is in short supply.
IPv6 Support
IPv6 functions such as Dual IPv4/IPv6 Stack, MLD Snooping, IPv6 ACL, DHCPv6 Snooping, IPv6 Interface, Path Maximum Transmission Unit (PMTU) Discovery and IPv6 Neighbor Discover guarantee your network is ready for the Next Generation Network (NGN) without upgrading your hardware.
Casos Relacionados
-
ISP Citynet
Omada Offers Citynet Reliable and High-Speed Data Transfer for Network Service
ISP Citynet
Omada Offers Citynet Reliable and High-Speed Data Transfer for Network Service
“I would like to emphasize that of the large number of devices deployed, not one of them has suffered any type of physical failure. There was a point at which the price of TP-Link’s Jetstream series was something we no longer considered important since they’re so reliable. We stopped looking at other manufacturers because we were so satisfied with the products we purchased.” —Skynet
CARACTERÍSTICAS DE HARDWARE | |
---|---|
Interface | • 16× 10/100/1000 Mbps RJ45 Ports• 2× Gigabit SFP Slots |
Quantidade de ventoinhas | Fanless |
Fonte de alimentação | 100-240 V AC~50/60 Hz |
Dimensões (L x P x A) | 17.3 × 7.1 × 1.7 in (440 × 180 × 44 mm) |
Mounting | Rack Mountable |
Max Power Consumption | 12.3 W (220 V/50 Hz) |
Max Heat Dissipation | 41.97 BTU/hr |
PERFORMANCE | |
---|---|
Switching Capacity | 36 Gbps |
Packet Forwarding Rate | 26.8 Mpps |
MAC Address Table | 8K |
Jumbo Frame | 9 KB |
FUNCIONALIDADES SOFTWARE | |
---|---|
Quality of Service | • 8 priority queues• 802.1p CoS/DSCP priority• Queue scheduling- SP (Strict Priority)- WRR (Weighted Round Robin)- SP+WRR• Bandwidth Control- Port/Flow based Rating Limiting• Smoother Performance• Action for Flows- Mirror (to supported interface)- Redirect (to supported interface)- Rate Limit- QoS Remark |
L3 Features | • 16 IPv4/IPv6 Interfaces• Static Routing- 48 static routes• Static ARP• 316 ARP Entries• Proxy ARP• Gratuitous ARP• DHCP Server• DHCP Relay• DHCP L2 Relay |
L2 and L2+ Features | • Link Aggregation- Static link aggregation- 802.3ad LACP- Up to 8 aggregation groups and up to 8 ports per group• Spanning Tree Protocol- 802.1d STP- 802.1w RSTP- 802.1s MSTP- STP Security: TC Protect, BPDU Filter, BPDU Protect, Root Protect, Loop Protect• Loopback Detection- Port-based- VLAN based• Flow Control- 802.3x Flow Control- HOL Blocking Prevention• Mirroring- Port Mirroring- CPU Mirroring- One-to-One- Many-to-One- Tx/Rx/Both |
L2 Multicast | • Supports 511 (IPv4, IPv6) IGMP groups• IGMP Snooping- IGMP v1/v2/v3 Snooping- Fast Leave- IGMP Snooping Querier- IGMP Authentication• IGMP Authentication• MVR• MLD Snooping- MLD v1/v2 Snooping- Fast Leave- MLD Snooping Querier- Static Group Config- Limited IP Multicast• Multicast Filtering: 256 profiles and 16 entries per profile |
Advanced Features | • Support Omada Hardware Controller (OC200/OC300), Software Controller, Cloud-Based Controller• Automatic Device Discovery• Batch Configuration• Batch Firmware Upgrading• Intelligent Network Monitoring• Abnormal Event Warnings• Unified Configuration• Reboot Schedule• ZTP (Zero-Touch Provisioning)* |
VLAN | • VLAN Group- Max 4K VLAN Groups• 802.1q Tagged VLAN• MAC VLAN: 12 Entries• Protocol VLAN: Protocol Template 16, Protocol VLAN 16• GVRP• VLAN VPN (QinQ)- Port-Based QinQ- Selective QinQ• Voice VLAN |
Access Control List | • Time-based ACL• MAC ACL- Source MAC- Destination MAC- VLAN ID- User Priority- Ether Type• IP ACL- Source IP- Destination IP- Fragment- IP Protocol- TCP Flag- TCP/UDP Port- DSCP/IP TOS- User Priority• Combined ACL• Packet Content ACL• IPv6 ACL• Policy- Mirroring- Redirect- Rate Limit- QoS Remark• ACL apply to Port/VLAN |
Security | • IP-MAC-Port Binding- DHCP Snooping- ARP Inspection- IPv4 Source Guard• IPv6-MAC-Port Binding- DHCPv6 Snooping- ND Detection- IPv6 Source Guard• DoS Defend• Static/Dynamic Port Security- Up to 64 MAC addresses per port• Broadcast/Multicast/Unicast Storm Control- kbps/ratio/pps control mode• IP/Port/MAC based access control• 802.1X- Port based authentication- Mac based authentication- VLAN Assignment- MAB- Guest VLAN- Support Radius authentication andaccountability• AAA (including TACACS+)• Port Isolation• Secure web management through HTTPS with SSLv3/TLS 1.2• Secure Command Line Interface (CLI) management with SSHv1/SSHv2 |
IPv6 | • IPv6 Dual IPv4/IPv6• Multicast Listener Discovery (MLD) Snooping• IPv6 ACL• IPv6 Interface• Static IPv6 Routing• IPv6 neighbor discovery (ND)• Path maximum transmission unit (MTU) discovery• Internet Control Message Protocol (ICMP) version 6• TCPv6/UDPv6• IPv6 applications- DHCPv6 Client- Ping6- Tracert6- Telnet (v6)- IPv6 SNMP- IPv6 SSH- IPv6 SSL- Http/Https- IPv6 TFTP |
Gestão | • Web-based GUI• Command Line Interface (CLI) through console port, telnet• SNMPv1/v2c/v3- Trap/Inform- RMON (1, 2, 3, 9 groups)• SDM Template• DHCP/BOOTP Client• 802.1ab LLDP/LLDP-MED• DHCP AutoInstall• Dual Image, Dual Configuration• CPU Monitoring• Cable Diagnostics• EEE• Password Recovery• SNTP• System Log |
MIBs | • MIB II (RFC1213)• Bridge MIB (RFC1493)• P/Q-Bridge MIB (RFC2674)• Radius Accounting Client MIB (RFC2620)• Radius Authentication Client MIB (RFC2618)• Remote Ping, Traceroute MIB (RFC2925)• Support TP-Link private MIBs• RMON MIB(RFC1757, rmon 1,2,3,9) |
GESTÃO | |
---|---|
Omada App | Yes. Requiring the use of OC300, OC200, Omada Cloud-Based Controller, or Omada Software Controller. |
Centralized Management | • Omada Cloud-Based Controller• Omada Hardware Controller (OC300)• Omada Hardware Controller (OC200)• Omada Software Controller |
Cloud Access | Yes. Requiring the use of OC300, OC200, Omada Cloud-Based Controller, or Omada Software Controller. |
Zero-Touch Provisioning | Yes. Requiring the use of Omada Cloud-Based Controller. |
Management Features | • Web-based GUI• Command Line Interface (CLI) through telnet• SNMPv1/v2c/v3• SNMP Trap/Inform• RMON (1,2,3,9 groups)• SDM Template• DHCP/BOOTP Client• Dual Image, Dual Configuration• CPU Monitoring• Cable Diagnostics• EEE• SNTP• System Log |
OUTROS | |
---|---|
Certificações | CE, FCC, RoHS |
Conteúdo da embalagem | • TL-SG2218 Switch• Power Cord• Quick Installation Guide• Rackmount Kit• Rubber Feet |
Requisitos de Sistema | Microsoft® Windows® 98SE, NT, 2000, XP, Vista™ or Windows 7/8/10/11, MAC® OS, NetWare®, UNIX® or Linux. |
Temperatura e Humidade | • Operating Temperature: 0–40 ℃ (32–104 ℉);• Storage Temperature: -40–70 ℃ (-40–158 ℉)• Operating Humidity: 10–90% RH non-condensing• Storage Humidity: 5–90% RH non-condensing |
*Zero-Touch Provisioning requires the use of Omada Cloud-Based Controller.