TL-SG2008P
JetStream 8-Port Gigabit Smart Switch with 4-Port PoE+
- 62 W PoE Budget: 4× 802.3at/af-compliant PoE+ ports with a total power supply of 62 W*.
- Full Gigabit Ports: 4× gigabit PoE+ ports and 4× gigabit non-PoE ports provide high-speed connections.
- Integrated into Omada SDN: Zero-Touch Provisioning**, Centralized Cloud Management, and Intelligent Monitoring.
- Centralized Management: Cloud access and Omada app for ultra convenience and easy management.
- Robust Security Strategies: IP-MAC-Port Binding, ACL, Port Security, DoS Defend, Storm control, DHCP Snooping, 802.1X, Radius Authentication, and more.
- Optimize Voice and Video Applications: L2/L3/L4 QoS and IGMP snooping.
Learn more about TP-Link PoE technology >
Centralized Management
Smarter Switching for Smarter Results
JetStream 8-Port Gigabit Smart Switch with 4-Port PoE+
TL-SG2008P
-
Centralized Management
-
Multi-Site Management
-
Omada App
-
Multicast Optimization
-
VLAN
-
Access Control List
-
62 W PoE Budget*
-
Durable Metal Casing
Multiple Application Scenarios
The TL-SG2008P is fully compatible with PoE devices, such as IP cameras, access points, and IP phones. It also works with non-PoE wired devices to provide gigabit connections, such as PCs, printers, and IPTV.
-
Surveillance
Works with IP Cameras
-
Conference Call
Works with IP Phones
-
Wi-Fi Coverage
Works with Omada EAPs
-
Wired Connections
Works with PCs and Printers
Power over Ethernet for Simplified Network Deployment
Features four 802.3af/at compliant PoE+ ports, the switch supports up to 62 W total PoE power budget.* Designed to use a single Ethernet cable for both data and power transmission, it offers flexible deployment for PoE-supported devices such as wireless access points, IP cameras, and IP phones, lowering infrastructure costs for small businesses.
Value-Added Features Bring Unexpected Experience
-
Access Control List (ACL)
ACL serves as a virtual admin, allowing all connected devices to obtain data in accordance with user-defined network rules and help you create the network regulations you need.
-
QoS for Lag-Free Experience
Designate the priority of traffic based on QoS, ensuring latency sensitive applications like voice and video, remain clear and lag-free.
-
VLAN for Security
Use VLAN to achieve logical grouping management of devices in different physical LANs, improve information security, and reduce data congestion.
Omada SDN—Smarter Cloud Solution for Business Networking
Omada Software Defined Networking (SDN) platform integrates network devices including access points, switches and gateways, guaranteeing powerful business network with higher efficiency, higher security, and higher reliability.
Hassle-Free Centralized Cloud Management:
100% centralized cloud management of whole network from different sites—all controlled from a single interface anywhere, anytime.
Easy Management with the Omada App
Follow configuration instructions on the free Omada app to get set up in minutes. Omada lets you configure settings, monitor the network status and manage clients, all from the convenience of a smart phone or tablet.
Аппаратные характеристики | |
---|---|
Стандарты и протоколы | IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3af, IEEE 802.3at, IEEE 802.3x, IEEE 802.1d, IEEE 802.1s, IEEE 802.1w, IEEE 802.1q, IEEE 802.1p, IEEE 802.1x |
Интерфейсы | • 8 портов 10/100/1000 Мбит/с (разъём RJ45) (порты 1-4 поддерживают 802.3at/af PoE+) • Автосогласование и Auto MDI/MDIX |
Среда передачи данных | • 10BASE-T: неэкранированная витая пара катерогий 3, 4, 5 (максимум 100 м) • 100BASE-TX/1000Base-T: неэкранированная витая пара категорий 5, 5e или выше (максимум 100 м) |
Вентиляторы | Без вентилятора |
Источник питания | • Внешний адаптер питания (выходной ток: 53,5 В постоянного тока / 1,31 А) |
Энергопотребление | • 7,9 Вт (220 В / 50 Гц) (без подключённого питаемого устройства) • 79,2 Вт (220 В / 50 Гц) (с подключённым питаемым устройством 62 Вт) |
Порты RJ45 с поддержкой PoE | • Стандарт: поддержка 802.3at/af • Порты PoE+: 4 порта • Питание: 62 Вт* |
Размеры (Ш × Д × В) | 209 × 126 × 26 мм |
Максимальное энергопотребление | • V1: 69.7 W (220 V/50 Hz) (with 62 W PD connected); 7.9 W (220 V/50 Hz) (no PD connected)• V2: 73.8 W (220 V/50 Hz) (with 62 W PD connected)• V3: 77.3 W (110 V/60 Hz) (with 62 W PD connected) |
Максимальное тепловыделение | • V1: 237.82 BTU/hr (220 V/50 Hz) (with 62 W PD connected); 26.95 BTU/hr (220 V/50 Hz) (no PD connected)• V2: 251.84 BTU/hr (220 V/50 Hz) (with 62 W PD connected)• V3: 263.6 BTU/hr (110 V/60 Hz) (with 62 W PD connected) |
Производительность | |
---|---|
Полоса пропускания / кросс-шина | 16 Гбит/с |
Таблица МАС-адресов | 8K |
Буфер памяти пакетов | 4,1 Мбит |
Размер кадра Jumbo | 9 КБ |
Характеристики программного обеспечения | |
---|---|
Приоритизация | • Приоритет 802.1p CoS/ DSCP • 8 приоритетных очередей • Режим приоритета очередей — SP (строгий приоритет) — WRR (Weighted Round Robin) • Queue Weight Config • Контроль пропускной способности — Ограничение скорости для портов/потоков • Защита от сетевых штормов — Несколько режимов контроля (kbps/ratio/pps) — Broadcast/Multicast/Unknown-Unicast Control |
Функции L2 и L2+ | • DHCP Relay — DHCP VLAN Relay • DHCP L2 Relay • Агрегирование каналов — Статическое агрегирование каналов — 802.3ad LACP — До 8 групп агрегирования на 8 портов per group • Протокол STP — 802.1D STP — 802.1w RSTP — 802.1s MSTP — STP Security: TC Protect, BPDU Filter/Protect, Root Protect • Обнаружение петель (Loopback Detection) • Управление потоком — 802.3x • Зеркалирование — Зеркалирование портов — Зеркалирование CPU — One-to-One — Many-to-One — На основе потока — Входящий трафик / Исходящий трафик / Весь трафик • Протокол DLDP • 802.1ab LLDP/ LLDP-MED |
Мультивещание 2-го уровня | • 511 IPv4, IPv6 общие Multicast-группы • IGMP Snooping — IGMP v1/v2/v3 Snooping — Fast Leave — IGMP Snooping Querier — Static Group Config • Multicast VLAN Registration (MVR) • Multicast-фильтрация • MLD Snooping — MLD v1/v2 Snooping — Fast Leave — MLD Snooping Querier — Static Group Config • Limited IP Multicast (256 профилей, по 16 групп на профиль) |
Дополнительные функции | • Automatic Device Discovery• Batch Configuration• Batch Firmware Upgrading• Intelligent Network Monitoring• Abnormal Event Warnings• Unified Configuration• Reboot Schedule |
Поддержка IPv6 | • IPv6 Dual IPv4/IPv6 • Multicast Listener Discovery (MLD) Snooping • Обнаружение соседей IPv6 • Обнаружение пути максимальной единицы передачи (MTU) • Протокол межсетевых управляющих сообщений (ICMP) версии 6 • TCPv6/UDPv6 • Приложения IPv6 — Клиент DHCPv6 — Ping6 — Tracert6 — Telnet(v6) — IPv6 SNMP — IPv6 SSH — IPv6 SSL — HTTP/HTTPS — IPv6 TFTP |
Виртуальные сети | • VLAN группы — Максимум 4K VLAN-групп • 802.1Q тег VLAN • MAC-адрес VLAN: 12 записей • Протокол VLAN • GVRP • Голосовой VLAN |
Список управления доступом | • Поддержка до 230 записей • Диапазон времени — Отрезок времени — Неделя — Абсолютный диапазон — Праздники • Список управления доступом (ACL) по времени • Список управления доступом (ACL) для MAC-адресов — MAC-адрес источника — MAC-адрес назначения — VLAN ID — Приоритет пользователя — EtherType • Список управления доступом (ACL) для IP-адресов — IP-адрес источника — IP-адрес назначения — IP-протокол — Флаг TCP — Порт источника TCP/UDP — Порт назначения TCP/UDP — Тип обслуживания DSCP/IP • Список управления доступом (ACL) IPv6 • Комбинированный список управления доступом (ACL) • Действия для правил — Разрешение/запрет • Действия для политик — Зеркалирование — Ограничение скорости — Перенаправление — Метка приоритизации (QoS) • Привязка правил ACL — Привязка портов — Привязка VLAN • Действия с потоками — Зеркалирование (на поддерживаемый интерфейс) — Перенаправление (на поддерживаемый интерфейс) — Ограничение скорости — Метка приоритизации (QoS) |
Безопасность | • AAA • 802.1X — Аутентификация по порту — Аутентификация по MAC-адресу (Host) — Метод аутентификации включает PAP/EAP-MD5 — MAB — Гостевой VLAN — Поддержка аутентификации и учёта RADIUS • Привязка IP/IPv6-MAC — 512 записей привязки — DHCP Snooping — DHCPv6 Snooping — ARP Inspection — Обнаружение соседей • Защита IP-адреса источника — 253 записи — IP-адрес источника + MAC-адрес источника • Защита IPv6-адреса источника — 183 записи — IPv6-адрес источника + MAC-адрес источника • Защита от DoS-атак • Статическая/динамическая/постоянная защита порта — До 64 MAC-адресов на порт • Защита от сетевых штормов Broadcast/Multicast/Unicast — kbps/ratio/pps • Изолирование портов • Защищённый веб-интерфейс HTTPS с SSLv3/TLS1.0 • Управление через защищённый интерфейс командной строки с SSHv1/SSHv2 • Контроль доступа по IP/порту/MAC |
Базы управляющей информации (MIB) | • MIB II (RFC1213) • Bridge MIB (RFC1493) • P/Q-Bridge MIB (RFC2674) • Клиент RADIUS Accounting MIB (RFC2620) • Клиент RADIUS Authentication MIB (RFC2618) • Remote Ping, Traceroute MIB (RFC2925) • Поддержка закрытых MIB TP-Link • RMON MIB (RFC1757, rmon 1,2,3,9) |
Управление | |
---|---|
Приложение Omada | Да |
Централизованное управление | • Облачный контроллер Omada • Аппаратный контроллер Omada (OC300) • Аппаратный контроллер Omada (OC200) • Программный контроллер Omada |
Облачный доступ | Да (через OC300, OC200, облачный контроллер Omada или аппаратный контроллер Omada) |
Автоматическая настройка параметров | Yes. Requiring the use of Omada Cloud-Based Controller (Supported by TL-SG2008P v1, v3 and above, while is not supported by TL-SG2008P v2) |
Управление | • Графический веб-интерфейс и интерфейс командной строки • SNMPv1/v2c/v3 • SNMP Trap/Inform • RMON (группы 1, 2, 3, 9) • Шаблон SDM • DHCP/BOOTP Client • Dual Image, Dual Configuration • Мониторинг CPU • Диагностика кабеля • EEE • Системный журнал • 802.1ab LLDP/ LLDP-MED |
Прочее | |
---|---|
Сертификация | CE, FCC, RoHS |
Комплект поставки | • TL-SG2008P • Адаптер питания • Руководство по настройке • Резиновые ножки |
Системные требования | Microsoft® Windows® XP, Vista™ или Windows 7, Windows 8, Windows 10, MAC® OS, NetWare®, UNIX® или Linux. |
Параметры окружающей среды | Рабочая температура: 0...+40 ℃ Температура хранения: –40...+70 ℃ Влажность воздуха при эксплуатации: 10–90% без образования конденсата Влажность воздуха при хранении: 5–90% без образования конденсата |
*PoE budget calculations are based on laboratory testing. Actual PoE power budget is not guaranteed and will vary as a result of client limitations and environmental factors.
**Zero-Touch Provisioning requires the use of Omada Cloud-Based Controller. Note that TL-SG2008P v2 doesn't support Omada Cloud-Based Controller. Go to https://www.tp-link.com/en/omada-cloud-based-controller/product-list/ to confirm which models are compatible with Omada Cloud-Based Controller.